Microbial Control Products
Resource Center



Peracetic Acid Test Kit and Test Strips

Today’s interest in environmentally friendly or “green” products has greatly increased the popularity of peracetic acid (PAA) as a sanitizer in food and beverage processing. It is one of the few treatment products approved for sanitizing foods carrying the “organic” label. Peracetic acid is also being used to bleach cotton, remove biofilms and sterilize medical instruments.

PAA is a combination of peroxyacetic acid and hydrogen peroxide. It breaks down to oxygen and acetic acid which has far less impact on the environment than other sanitizers. This makes it ideal for rinsing applications since it requires much less water than traditional sanitizers to remove surface residuals. It is widely used in fruit and vegetable washing, breweries, beverage plants, wineries and even in the dialysis area. Since it can also be used over broad temperature and pH ranges it has several advantages over other sanitizers.

Testing Peracetic Acid

The 7191-01-FMC titration kit can measure either PAA in 15 ppm increments or Peroxide concentrations in 50 ppm increments. There are also 3 ranges of PAA test strips available covering low (0-50 ppm), medium (0-160 ppm) and high (0- 1,000 ppm) range concentrations.

Peracetic Acid Test Kit

The 7191-01-FMC is a dropper bottle titration kit for hydrogen peroxide and peroxyacetic acid. The hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence.

Order Code

Test System

Range / Sensitivity

# Tests
(# Reagents)

Weight/lbs

7191-01-FMC

Dropper Bottle

1 drop = 50 ppm Peroxide
1 drop = 15 ppm Peracetic Acid

50 (5)

2

Reagents

When titrating Peracetic Acid, some kit reagents may run out  before others. We offer the reagents below to extend the use of FMC’s Test Kit.

6141WT-G
6155-L
6410-L

Sulfuric Acid Reagent Replacement Bottle
Peracetic Acid Titrant (Sodium Thiosulfate) Replacement Bottle
Ferroin Indicator Replacement Bottle

Peracetic Acid Test Strips

The Insta-Test 3000 test strips determine peracetic acid concentrations from 0-160 ppm. The test has a 10 second development time. The container contains 50 strips and has a desiccant liner and tight snap-cap to protect from moisture. Low and high range strips are also available.

Order Code

Range

3000

0, 10, 20, 40, 60, 85, 160 ppm Peracetic Acid

3000LR

0, 5, 10, 20, 30, 50 ppm Peracetic Acid

3000HR

0, 50, 100, 250, 500, 1000 ppm Peracetic Acid