Peracetic Acid Test Kit and Test Strips
|
|
Today’s interest in environmentally friendly or “green” products has greatly increased the popularity of peracetic acid (PAA) as a sanitizer in food and beverage processing. It is one of the few treatment products approved for sanitizing foods carrying the “organic” label. Peracetic acid is also being used to bleach cotton, remove biofilms and sterilize medical instruments.
PAA is a combination of peroxyacetic acid and hydrogen peroxide. It breaks down to oxygen and acetic acid which has far less impact on the environment than other sanitizers. This makes it ideal for rinsing applications since it requires much less water than traditional sanitizers to remove surface residuals. It is widely used in fruit and vegetable washing, breweries, beverage plants, wineries and even in the dialysis area. Since it can also be used over broad temperature and pH ranges it has several advantages over other sanitizers.
Testing Peracetic Acid
The 7191-01-FMC titration kit can measure either PAA in 15 ppm increments or Peroxide concentrations in 50 ppm increments. There are also 3 ranges of PAA test strips available covering low (0-50 ppm), medium (0-160 ppm) and high (0- 1,000 ppm) range concentrations. |
Peracetic Acid Test Kit |
|
The 7191-01-FMC is a dropper bottle titration kit for hydrogen peroxide and peroxyacetic acid. The hydrogen peroxide equivalence is 1 drop = 50 ppm. The peracetic acid equivalence can be modified to test different concentrations by using a different sample size. The result is a 1 drop = 6, 15, or 300 ppm equivalence. |
|
Order Code |
Test System |
Range / Sensitivity |
# Tests (# Reagents) |
Weight/lbs |
|
7191-01-FMC |
Dropper Bottle |
1 drop = 50 ppm Peroxide 1 drop = 15 ppm Peracetic Acid |
50 (5) |
2 |
|
|
Reagents |
|
When titrating Peracetic Acid, some kit reagents may run out before others. We offer the reagents below to extend the use of FMC’s Test Kit. |
|
6141WT-G 6155-L 6410-L |
Sulfuric Acid Reagent Replacement Bottle Peracetic Acid Titrant (Sodium Thiosulfate) Replacement Bottle Ferroin Indicator Replacement Bottle |
|
|
|
Peracetic Acid Test Strips |
|
The Insta-Test 3000 test strips determine peracetic acid concentrations from 0-160 ppm. The test has a 10 second development time. The container contains 50 strips and has a desiccant liner and tight snap-cap to protect from moisture. Low and high range strips are also available. |
|
Order Code |
Range |
|
3000 |
0, 10, 20, 40, 60, 85, 160 ppm Peracetic Acid |
|
3000LR |
0, 5, 10, 20, 30, 50 ppm Peracetic Acid |
|
3000HR |
0, 50, 100, 250, 500, 1000 ppm Peracetic Acid |